Australian charger specialists · Knoxfield, Victoria Call (03) 9764 8444Review site · Stripe sandbox
Model specifications

SFX48-18

High output three phase · published single-output ratings

Stanbury
Illustrative Stanbury high output three phase range image

Range image; exact model appearance may vary.

Electrical specifications

ModelSFX48-18
Rated power18 kW
AC voltage400 V
Phases3
AC current31 A

Published DC output

Battery voltageMaximum current
24 V nominal battery420 A maximum
36 V nominal battery420 A maximum
48 V nominal battery360 A maximum
Archived 2026-02v1 catalogue ratings. This model was absent from the reviewed public service; confirm current specification and availability. These are published single-output ratings. Confirm battery profile, charge limits, connectors, actual input configuration and installation before purchase. This concept specification sheet is not an approved order configuration.

Download original catalogue (PDF, 4.7 MB)

Using these specifications

Match the charger to the battery.

This three-phase model supports the battery voltages listed in its output table: 24 V / 36 V / 48 V. Output current changes with battery voltage. We select the 48 V or 80 V model range and charging profiles around the batteries in your fleet.

Is the maximum current the charging current?

The table gives the charger’s published maximum output at each voltage. The planned current can be lower to suit the battery’s approved limits, charging profile or site supply. The selector shows those separately.

What changes for an outdoor installation?

The model ratings describe the charger. An outdoor build also needs the appropriate enclosure, mounting, connections and site review.

What should I check before choosing?

Record the battery voltage, chemistry, capacity, permitted charging current and connector. Check the available AC supply and plug. For lithium, include the battery’s BMS and communication requirements.

Typical use

SFX48-18 is a 18 kW option for industrial fleet charging, with up to 360 A at 48 V from 3-phase 400 V AC supply. Match the battery voltage to the full output table above; the battery-approved planned current may be lower than the hardware maximum.

Compare with

Lower output: SFX48-17 · 17 kW · 340 A at 48 V